12 mm and reservoir sensors suitable for SIP, CIP and autoclavable applications for pH, dissolved oxygen and Redox measurement.




CIP Cleaning


The CIP system consists of a CIP package unit, CIP supply and return transfer panels, and connecting lines between the user process tanks and the CIP package unit. The CIP package unit is supplied with the utilities WFI, USP purified water, plant steam, and sterile filtered process air. The package unit is also supplied with caustic and acid solutions from the drums by metering pumps. CIP package unit can consist of two liquid tanks, a CIP heater, a CIP supply pump, and a control and instrumentation system for automation of sequence operation.


Sensors and Conditions



pH Sensors for CIP Cleaning



Goal of Measurement:
Control of the CIP solution

Range: Resolution: Interference: Sensor Type: Armatures:
pH 0 to pH 14 0.2 pH None -- FLEXIFIT TC
         
Other Conditions: Applications: Benefit of Sensor:
Strong acid and caustic solutions N/A Stability under CIP conditions.



Conductivity Sensors for CIP Cleaning



Goal of Measurement:
Quality control after CIP

Range: Resolution: Interference: Sensor Type: Armatures:
10uS – 200 mS 1% None CONDUCELL 4US
CONDUCELL 4USF
CONDUCELL 4USF ARC
FLEXIFIT BIO
FLEXIFIT TC
         
Other Conditions: Applications: Benefit of Sensor:
None N/A N/A

Part Number
Description
Quantity
 242162
Conducell 4USF Arc 425
  
 242161
Conducell 4USF Arc 325
  
 242160
Conducell 4USF Arc 225
  
 242159
Conducell 4USF Arc 120
  
 237620
Conducell 4USF-PG 120
  
Conducell 4US-G125
  
 237750
Conducell 4US-T150-50
  
 237760
Conducell 4US-T150-100